| ====== Scale and Range of Analog Signals ====== | ====== Scale and Range of Analog Signals ====== | ||
| - | Within EEROS we work with signals having physically meaningful units. However, when such signals are read from real-world hardware we use analog-to-digital converters or encoder which are basically counters. When outputting such signals we use digital-to-analog converters. These counters or converters all deliver or need an integer value. Its maximum and minimum value depend on the resolution of the underlying hardware. The '' | + | Within EEROS we work with signals having physically meaningful units. However, when such signals are read from real-world hardware we use analog-to-digital converters or encoder which are basically counters. When outputting such signals we use digital-to-analog converters. These counters or converters all deliver or need an integer value. Its maximum and minimum value depend on the resolution of the underlying hardware. The '' | 
| ===== Configuring an Analog Output ===== | ===== Configuring an Analog Output ===== | ||
| Line 9: | Line 9: | ||
| - Enter this limits in the configuration file under '' | - Enter this limits in the configuration file under '' | ||
| - Write a small digital value to the analog output directly (not through eeros). That is, if your are using comedi for instance, you use a user interface and write a value of 1000 to one of its analog outputs. | - Write a small digital value to the analog output directly (not through eeros). That is, if your are using comedi for instance, you use a user interface and write a value of 1000 to one of its analog outputs. | ||
| - | - Record this digital value it in the configuration file under '' | + | - Record this digital value in the configuration file under '' | 
| - Measure the resulting voltage with a multimeter and record it in the configuration file under '' | - Measure the resulting voltage with a multimeter and record it in the configuration file under '' | ||
| - Repeat this with a large digital value close to the upper limit. For this you have to know the range of your digital-to-analog converter. | - Repeat this with a large digital value close to the upper limit. For this you have to know the range of your digital-to-analog converter. | ||
| - | - Record this digital value it in the configuration file under '' | + | - Record this digital value in the configuration file under '' | 
| - Measure the resulting voltage with a multimeter and record it in the configuration file under '' | - Measure the resulting voltage with a multimeter and record it in the configuration file under '' | ||