eeros_architecture:hal:scaling
                This is an old revision of the document!
Scale and Range of Analog Signals
Within eeros we work with signals having physically meaningful units. However, when such signals are read from real-world hardware we use analog-to-digital converters or encoder which are basically counters. When outputting such signals we use digital-to-analog converters. These counters or converters all deliver or need an integer value. Its maximum and minimum value depend on the resolution of the underlying hardware. The scale and range key allows to convert between the necessary integer value and the physically meaningsful signals.
Configuring an Analog Output
To configure such a channel follow these steps:
- Read the datasheet of your hardware and note the upper and lower limits of the analog output voltage.
- Enter this limits in the configuration file underrangewithminOutandmaxOut.
- Get the upper and lower limits of the digital values of the converter from the datasheet.
- Enter this limits in the configuration file underrangewithminInandmaxIn.
- Write a small digital value to the analog output directly (not through eeros). That is, if your are using comedi for instance, you use a user interface and write a value of 1000 to one of its analog outputs.
- Record this value it in the configuration file underscaleasminIn
- Measure the resulting voltage with a multimeter and record it in the configuration file underscaleasminOut.
- Repeat this with a large digital value close to the upper limit. For this you have to know the range of your digital-to-analog converter.
- Record this value it in the configuration file underscaleasmaxIn
- Measure the resulting voltage with a multimeter and record it in the configuration file as underscalemaxOut.
The resulting channel configuration for a 16bit DAC might look like:
  "channel0": {
    "signalId": "dacOut0",
    "scale": [ { "id" : "dac",
                 "minIn":    1000, "maxIn":  64000,
                 "minOut": -9.787, "maxOut": 9.923 } ],
    "range": [ { "id" : "dac",
                 "minIn":       0, "maxIn":  65536,
                 "minOut":  -10.0, "maxOut":  10.0 } ],
    "unit": "V"
  }
eeros_architecture/hal/scaling.1494495934.txt.gz · Last modified: 2017/05/11 11:45 by graf
                
                