eeros_architecture:control_system:blocks
                Differences
This shows you the differences between two versions of the page.
| Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
| eeros_architecture:control_system:blocks [2017/03/17 12:07] – [Signals] graf | eeros_architecture:control_system:blocks [2022/04/19 12:36] (current) – [Predefined Blocks] ursgraf | ||
|---|---|---|---|
| Line 3: | Line 3: | ||
| ===== Inputs and Outputs ===== | ===== Inputs and Outputs ===== | ||
| - | Every output carries a signal. An input can be connected to an output and simply refers to the signal of this connected output. | + | Every output carries a [[eeros_architecture: | 
| [{{ block.png? | [{{ block.png? | ||
| This makes sure that each input is connected to a single output. On the other hand, an output can carry its signal to many inputs. | This makes sure that each input is connected to a single output. On the other hand, an output can carry its signal to many inputs. | ||
| Line 12: | Line 12: | ||
| Step<> | Step<> | ||
| step.setName(" | step.setName(" | ||
| - | step.getOut().getSignal().setName(" | ||
| Sum< | Sum< | ||
| sum.setName(" | sum.setName(" | ||
| - | sum.getOut().getSignal().setName(" | ||
| sum.getIn(0).connect(step.getOut()); | sum.getIn(0).connect(step.getOut()); | ||
| - | Gain<> | + | Gain<Vector2> posController(174.5); | 
| posController.setName(" | posController.setName(" | ||
| </ | </ | ||
| Line 27: | Line 25: | ||
| Output signals are created together with the blocks. On the other side, there is no need to generate and name input signals. | Output signals are created together with the blocks. On the other side, there is no need to generate and name input signals. | ||
| + | For most blocks you have to specify the signal types on its inputs or outputs with template parameters, see [[tools: | ||
| Line 38: | Line 37: | ||
| // | // | ||
| + | ===== Initial State of Outputs ===== | ||
| + | All outputs of any block carry a value of NaN (not a number) after the block has been created. Only after the first execution of its run-method does the signal have a meaningful value. | ||
eeros_architecture/control_system/blocks.1489748864.txt.gz · Last modified: 2017/03/17 12:07 by graf
                
                