eeros_architecture:sequencer:monitors
Differences
This shows you the differences between two versions of the page.
Both sides previous revisionPrevious revisionNext revision | Previous revision | ||
eeros_architecture:sequencer:monitors [2017/09/13 17:38] – [Assign a Condition to a Monitor] graf | eeros_architecture:sequencer:monitors [2021/10/20 16:07] (current) – [Define your own Condition] ursgraf | ||
---|---|---|---|
Line 16: | Line 16: | ||
}; | }; | ||
</ | </ | ||
+ | The method // | ||
+ | |||
IMPORTANT Every Sequence or step already has a timeout condition (of class '' | IMPORTANT Every Sequence or step already has a timeout condition (of class '' | ||
+ | |||
+ | IMPORTANT Make sure that your condition is properly set and reset. To give an example: A condition might be the state of a button. As soon as the button is pressed, the condition might return '' | ||
===== Assign a Condition to a Monitor ===== | ===== Assign a Condition to a Monitor ===== | ||
The second step is to define a monitor and assign it a condition. | The second step is to define a monitor and assign it a condition. |
eeros_architecture/sequencer/monitors.1505317127.txt.gz · Last modified: 2017/09/13 17:38 (external edit)