-====== Control System with One Time Domain ====== 
-In the EEROS library you will find a directory with examples. Open a shell in the build directory of your EEROS library and run ''examples/controlsystem/PeriodicExample1''. 
-This examples does: 
-  * Creates a main task //ss// with an execution period of five milliseconds. The task itself is defined of type ''Lambda'' with a run method given by an empty lambda function.  
-  * Creates a time domain //t1// with a period of five milliseconds.  
  
-Both harmonic tasks have a periodic counter which measure its periods and run times. Once every 1000th run the results are logged. The results are printed in units of seconds.  
-Additionally both harmonics have a default monitor function added. This monitor function logs a warning if the measured period differs more than 5%. Depending on your hardware platform and realtime support of your operating system you might get no warnings, several or many warnings. 