CANopen Send

This block sends PDO packets over a CAN bus to one or several drives. The drives itself must be initialized by SDO transfers and brought into operational state where PDO transfer is possible. The control system must incorporate a block for sending and another one for receiving CAN messages.

Control system for CANopen together with timeline

The block for sending will periodically (given by its time domain) send a synq message followed by several PDO's. It is important that this block is run after the block for receiving CAN messages. This ensures that the drives can send their messages upon receiving the synq message and the receive block already has these messages in its receive buffer and does not block when running.

Data Transfer

Each time the block is run by its time domain, a sync message is sent followed by one or several RPDOs to all connected nodes. Each PDO carries one or more CANopen objects. See https://gitlab.ost.ch/tech/inf/public/canopenlib/-/blob/master/demo/demo.md#demo-1 for the configuration of the PDOs. Make sure, that you send the RPDO exactly as your drive expects it. The CANopen Send block has several inputs as shown below.

and RPDO2 (velocity). While the control word can be set by the method

setCtrl(Matrix<nofNodes,1,uint16_t>);

the velocity is taken from its input vel.
The velocity input expects a signal in SI units, e.g. rad/s. To account for encoder resolution of the actual drive together with a gearbox, it is possible to set a scaling factor with

setVelScale(Matrix<nofNodes,1,double>);

This blocks uses the CANopen Library. Make sure to install this library following https://wiki.eeros.org/getting_started/install_wrapper#canopen.